Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Key Attributes
- Creates permanent electrical connections
- Extended working time
- Low cure temperature of 65 °C
- Room temperature storage
- Long shelf life
- NASA low outgassing approved
Applications & Uses
- Applications
- Application Area
- Application Method
- Cure Method
- Recommended Preparation
Clean the substrate with Isopropyl Alcohol, MG #824, so the surface is free of oils, dust, and other residues.
- Syringe
- Twist and remove the cap from the syringe. Do not discard cap.
- Measure 1 part by volume of A.
- Measure 1 part by volume of B.
- Dispense material on a mixing surface or container, and thoroughly mix parts A and B together.
- To stop the flow, pull back on the plunger.
- Clean nozzle to prevent contamination and material buildup.
- Replace the cap on the syringe.
- Can
- Stir each part individually to re-incorporate material that may have separated.
- Measure 1.2 part by weight of A.
- Measure 1 part by weight of B.
- Thoroughly mix parts A and B together.
- Apply adhesive to the application area.
- Cure Instructions
The product will not cure at room temperature. Cure the adhesive in an oven at one of these time/temperature options:
- 2 h @ 65 ˚C
- 1 h @ 80 ˚C
- 30 min @ 100 ˚C
Properties
- Physical Form
- Thermal Properties
- Typical Properties
- Cured Properties
- Uncured Properties
Value | Units | Test Method / Conditions | |
Thermal Conductivity (at 25 ˚C) | 1.3 | W/(m·K) | — |
Value | Units | Test Method / Conditions | |
Mix Ratio | 1:1 | Volume | — |
Mix Ratio | 1.2:1 | Weight | — |
Viscosity (at 25 ˚C)ᴬ | 950 | Pa·s | — |
Viscosity (at 25 ˚C)ᴮ | 6200 | Pa·s | — |
Working Time | 4 | Hours | — |
Value | Units | Test Method / Conditions | |
Compressive Strength | 65 | N/mm2 | — |
CTE After Tg | 158 | ppm/˚C | — |
CTE Prior Tg | 78 | ppm/˚C | — |
Glass Transition Temperature (Tg) | 34 | ˚C | — |
Hardness Shore D | 60 | — | — |
Lap Shear (Aluminum) | 7.1 | N/mm2 | — |
Lap Shear (Stainless steel) | 4.5 | N/mm2 | — |
Outgassing (at 125 ˚C for 24 h) | 0.4 | % | — |
Resistivity | 1.0 x 10⁻³ | Ω·cm | — |
Service Temperature Range | -40 to 150 | ˚C | — |
Tensile Strength | 14 | N/mm2 | — |
Water Absorption | 0.1 | % | — |
Value | Units | Test Method / Conditions | |
Mixed Density | 2.42 | g/mL | — |
Regulatory & Compliance
- Certifications & Compliance
- Chemical Inventories
Packaging & Availability
- Available Packaging
Cat. No. Packaging Net Vol. Net Wt. 8331S-15G 2 Syringe kit 6 mL 14.7 g 8331S-50ML 2 Jar kit 50 mL 123 g 8331S-200ML 2 Can kit 200 mL 491 g
Storage & Handling
- Shelf Life
- 3 Years
- Storage Details
Store between 16 and 27 ˚C in a dry area, away from sunlight (see SDS). To maximize shelf life, recap product firmly when not in use.