Ketron® LSG FG PEEK is a product available in the form of plates and rods and boasts a range of features including X-ray sterilizability, high stiffness, life science grade, gamma sterilizability, excellent mechanical strength, heat resistance, steam sterilizability, heat sterilizability, plasma gas sterilizability, chemical resistance, ethylene oxide sterilizability, and biocompatibility. It is offered in both beige and black colors and is suitable for applications in equipment and parts, particularly connectors.

Polymer Name: Polyetheretherketone (PEEK)

Physical Form: Plates, Rods

Features: Biocompatible, Chemical Resistant, Ethylene Oxide Sterilizable, Excellent Mechanical Strength, Gamma Sterilizable, Heat Resistance, Heat Sterilizable, High Stiffness, Life Science Grade, Plasma Gas Sterilizable, Steam Sterilizable, X-Ray Sterilizable

Density: 1310.0 - 1310.0 kg/m³

Tensile Modulus: 4300.0 - 4300.0 MPa

Color: Beige, Black

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Technologies

Features & Benefits

Product Highlights
  • Two options – Life Science Grade and Life Science Grade + Food Grade. Exhibits high stiffness and mechanical strength.
  • Components are also sterilizable by means of steam (autoclave), dry heat, EtO, plasma, and gamma- & x-ray irradiation.
  • Pre-assessed for biocompatibility on both resin and shape for up to 24 hours contact with body tissue according to USP VI and ISO 10993, as well as wetted contact in bioprocessing.
  • Standard food approvals include FDA 21 CFR § 177.2415, while the FG type also includes Regulation (EU) No. 10/2011 food contact approval (which is based on food-related extractable & leaching tests).
    • Excellent sterilization resistance via steam, dry heat, Ethylene Oxide, plasma, gamma and x-ray
    • Unfilled PEEK base for high mechanical strength and chemical resistance
    • Exceptional heat resistance

Applications & Uses

Plastics & Elastomers Processing Methods
Recommended Applications
  • Those in which the duration of contact with human body tissue is limited up to 24 hours*, as well as wetted contact in bioprocessing.
  • This material is an excellent candidate for applications in the medical and bioprocessing fields, such as endoscopes/laparoscopes, manifolds, valves, connectors, lids, and adapters.

Properties

Flame Rating
Physical Form
Odor
Odorless
Insoluble in
Water
Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Strength ⁶115.0MPaISO 527-1/-2 ⁷
Tensile Strain (elongation, at yield) ⁶5.0%ISO 527-1/-2 ⁷
Tensile Strain (elongation, at break) ⁶17.0%ISO 527-1/-2 ⁷
Tensile Modulus of Elasticity ⁶4300.0MPaISO 527-1/-2 ⁹
Shear Strength ⁶55.0psiASTM D732
Compressive Stress (at 1% nominal strain) ⁶38.0MPaISO 604 ¹⁰
Compressive Stress (at 2% nominal strain) ⁶75.0MPaISO 604 ¹⁰
Compressive Stress (at 5% nominal strain) ⁶140.0MPaISO 604 ¹⁰
Charpy Impact Strength - Unnotched ⁶no breakkJ/m²ISO 179-1/1eU
Charpy Impact Strength - Notched ⁶3.5kJ/m²ISO 179-1/1eA
Flexural Strength ⁶170.0MPaISO 178 ¹²
Flexural Modulus of Elasticity ⁶600.0ksiASTM D790
Rockwell M Hardness ⁶ ¹⁴105.0ISO 2039-2
Rockwell R Hardness ⁶ ¹⁴126.0ASTM 2240
Typical Properties
ValueUnitsTest Method / Conditions
Thermal Decompositionmin. 400°C
Self Ignition Temperature595.0°CASTM D 1929
Density1.31g/cm³ISO 1183-1
Specific Gravity1.31ASTM D792
Water Absorption (after 24h immersion in water of 23 °C)0.1%ASTM D570 ¹⁷
Water Absorption (at saturation in water of 23 °C)0.45%ASTM D570 ¹⁷
Wear Rate28.0μm/kmISO 7148-2 ¹⁸
Dynamic Coefficient of Friction (-)0.3 - 0.5ISO 7148-2 ¹⁸
Limiting PV (at 100 FPM)8500.0ft.lbs/in².minQTM 55007 ²¹
Limiting PV (at 0.1 / 1 m/s cylindrical sleeve bearings)0.33 / 0.21
Thermal Properties
ValueUnitsTest Method / Conditions
Melting Temperature (DSC, at 10°C) ¹340.0°CISO 11357-1/-3
Thermal Conductivity (at 23°C) ¹0.25W/(K.m)
Coefficient of Linear Thermal Expansion (at -40 to 150 °C) ¹26.0μin./in./°FASTM E-831 (TMA)
Coefficient of Linear Thermal Expansion (at 23 to 60°C) ¹50.0μm/(m.K)
Coefficient of Linear Thermal Expansion (at 23 to 100°C) ¹55.0μm/(m.K)
Coefficient of Linear Thermal Expansion (above 150°C) ¹130.0μm/(m.K)
Heat Deflection Temperature (method A, 1.8 MPa) ¹160.0°CISO 75-1/-2
Continuous Allowable Service Temperature in Air (for 20 hrs) ¹ ³250.0°C
Service Temperature ¹ ⁴-50.0°C
Flammability UL 94 (3 mm) ¹ ⁵V - 0
Flammability Oxygen Index ¹35.0%ISO 4589-1/-2
Electrical Properties
ValueUnitsTest Method / Conditions
Electric Strength24.0kV/mmIEC 60243-1 ¹⁵
Volume Resistivity1 x 10¹⁴Ohm.cmIEC 62631-3-1
Surface Resistivity1 x 10¹³Ohm/sq.ANSI/ESD STM 11.11
Dielectric Constant (at 1 MHz)3.2IEC 62631-2-1
Dissipation Factor (at 1MHz)0.001IEC 62631-2-1
Note

Handling (Machining) :

  • During machining of the semi-finished products, evacuate swarf to prevent slipping or tripping hazard and observe the maximum allowable concentration of dust and
  • formaldehyde levels on the workplace which apply in your country.
  • Wear safety goggles during machining.

Storage:

  • The products shall be stored indoors in a normal environment (air at 10 - 30°C / 30 - 70% RH) and kept away from any source of degradation such as sunlight, UV-lamps, chemicals (direct or indirect contact), ionizing radiation, flames, etc.
  • Dimensional changes (camber, warpage, shrinkage …) of the products as well as slight color shifts of the external surfaces can occur with time.
  • The latter does generally not pose a problem in case of semi-finished products since the surface-layer is mostly removed anyway upon machining them into finished parts.

Safety measures:

  • Standard industrial safety recommendations shall be observed.
  • Temperatures above the melting temperature shall be avoided.

Regulatory & Compliance

Quality Standards

Storage & Handling

Storage and Handling Information

Handling (Machining) :

  • During machining of the semi-finished products, evacuate swarf to prevent slipping or tripping hazard and observe the maximum allowable concentration of dust and
  • formaldehyde levels on the workplace which apply in your country.
  • Wear safety goggles during machining.

Storage:

  • The products shall be stored indoors in a normal environment (air at 10 - 30°C / 30 - 70% RH) and kept away from any source of degradation such as sunlight, UV-lamps, chemicals (direct or indirect contact), ionising radiation, flames, etc.
  • Dimensional changes (camber, warpage, shrinkage …) of the products as well as slight colour shifts of the external surfaces can occur with time.
  • The latter does generally not pose a problem in case of semi-finished products since the surface-layer is mostly removed anyway upon machining them into finished parts.

Safety measures:

  • Standard industrial safety recommendations shall be observed.
  • Temperatures above the melting temperature shall be avoided.