Knowde Enhanced TDS
Identification & Functionality
- Additives Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Materials Features
Applications & Uses
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Mechanical Properties
- Physical Properties
- Typical Properties
- Electrical Properties
- Impact Properties
- Flame Characteristics
- Note
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
- ¹⁹ Wire and cable - UL 1581 tested on 2.0mm wire with 0.12mmx20 stranded copper
Value | Units | Test Method / Conditions | |
Tensile Stress (Break, Type I, 50 mm/min) ¹¹ | 18 | MPa | ASTM D638 |
Tensile Strain (Break, Type I, 50 mm/min) ¹¹ | 140 | % | ASTM D638 |
Flexural Modulus (at 12.5 mm/min, 100 mm span) ¹¹ | 100 | MPa | ASTM D790 |
Hardness (Shore A, 30S reading) ¹¹ | 87 | — | ASTM D2240 |
Tensile Stress (Break, 50 mm/min) ¹¹ | 18 | MPa | ISO 527 |
Tensile Strain (Break, 50 mm/min) ¹¹ | 130 | % | ISO 527 |
Flexural Modulus (at 12.5 mm/min) ¹¹ | 100 | MPa | ISO 178 |
Value | Units | Test Method / Conditions | |
Specific Gravity ¹¹ | 1.06 | — | ASTM D792 |
Melt Flow Rate (at 250°C, 5 kgf) ¹¹ | 15 | g/10 min | ASTM D1238 |
Value | Units | Test Method / Conditions | |
Tensile Strength (Break) ¹⁹ | 30 | MPa | UL 1581 |
Tensile Elongation (Break) ¹⁹ | 280 | % | UL 1581 |
Tensile Strength (Break, after 7days, at 136°C) ¹⁹ | 27 | MPa | UL 1581 |
Tensile Elongation (Break, after 7days, at 136°C) ¹⁹ | 200 | % | UL 1581 |
UL Temperature Rating ¹⁹ | 105 | °C | UL 1581 |
Heat Deformation (at 121°C, 250g) ¹⁹ | 20 | % | UL 1581 |
Value | Units | Test Method / Conditions | |
Volume Resistivity ¹¹ | 2.40E+16 | Ω.cm | ASTM D257 |
Dielectric Strength (in oil, at 1.5mm) ¹¹ | 28 | kV/mm | IEC 60243-1 |
Relative Permittivity (1 MHz) ¹¹ | 2.6 | — | IEC 60250 |
Dissipation Factor (at at 1 MHz) ¹¹ | 0.0028 | — | IEC 60250 |
Comparative Tracking Index ¹¹ | 600 | V | IEC 60112 |
Value | Units | Test Method / Conditions | |
Brittleness Temperature ¹¹ | -40 | °C | ASTM D746 |
Value | Units | Test Method / Conditions | |
Oxygen Index (LOI) | 28 | % | ISO 4589 |
Smoke Density (on 0.5mm plaque, Non-Flame, Ds-max) | 67 | — | ASTM E662 |
Smoke Density (on 0.5mm plaque, Flame, Ds-max) | 143 | — | ASTM E662 |
Glow Wire Flammability Index (passes at 960°C) | 3 | mm | IEC 60695-2-12 |
Glow Wire Ignitability Temperature (at 3.0 mm) | 825 | °C | IEC 60695-2-13 |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability