Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Electrical Properties
- Impact Properties
- Injection Molding
- Flame Characteristics
- Note
- ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
- ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
- ¹⁷ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card. The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
Value | Units | Test Method / Conditions | |
Tensile Stress (Break, Type I, 5 mm/min) ¹¹ | 120 | MPa | ASTM D638 |
Tensile Strain (Break, Type I, 5 mm/min) ¹¹ | 3.2 | % | ASTM D638 |
Tensile Modulus (at 5 mm/min) ¹¹ | 8630 | MPa | ASTM D638 |
Flexural Strength (at 1.3 mm/min, 50 mm span) ¹¹ | 180 | MPa | ASTM D790 |
Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹ | 8.10E+03 | MPa | ASTM D790 |
Tensile Stress (Break, 5 mm/min) ¹¹ | 122 | MPa | ISO 527 |
Tensile Strain (Break, 5 mm/min) ¹¹ | 3 | % | ISO 527 |
Tensile Modulus (at 1 mm/min) ¹¹ | 8100 | MPa | ISO 527 |
Flexural Strength (at 2 mm/min) ¹¹ | 185 | MPa | ISO 178 |
Flexural Modulus (at 2 mm/min) ¹¹ | 7200 | MPa | ISO 178 |
Value | Units | Test Method / Conditions | |
Specific Gravity ¹¹ | 1.45 | — | ASTM D792 |
Density ¹¹ | 1.44 | g/cm³ | ISO 1183 |
Density ¹¹ | 1.44E+00 | g/cm³ | ASTM D792 |
Moisture Absorption (at 23°C, 50% RH, 24hrs) ¹¹ | 7.00E-02 | % | ASTM D570 |
Moisture Absorption (at 23°C, 50% RH) ¹¹ | 0.07 | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Heat Deflection Temperature (at 0.45 MPa, 3.2 mm, Unannealed) ¹¹ | 144 | °C | ASTM D648 |
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹ | 140 | °C | ASTM D648 |
Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ | 146 | °C | ISO 75/Bf |
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ | 142 | °C | ISO 75/Af |
Relative Temperature Index (Electrical) ᵖ ¹¹ | 125 | °C | UL 746B |
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ | 115 | °C | UL 746B |
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ | 125 | °C | UL 746B |
Value | Units | Test Method / Conditions | |
High Ampere Arc Ignition (PLC 2) ¹⁷ | min. 3 | mm | UL 746A |
High Ampere Arc Ignition (PLC 4) ¹⁷ | min. 1.5 | mm | UL 746A |
High Voltage Arc Track Rate (PLC) ¹⁷ | 4 | PLC Code | UL 746A |
Hot Wire Ignition (PLC 0) ¹⁷ | min. 1.5 | mm | UL 746A |
Value | Units | Test Method / Conditions | |
Izod Impact (Unnotched, at 23°C) ¹¹ | 914 | J/m | ASTM D4812 |
Izod Impact (Notched, at 23°C) ¹¹ | 155 | J/m | ASTM D256 |
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ | 58 | kJ/m² | ISO 180/1U |
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ | 14 | kJ/m² | ISO 180/1A |
Value | Units | Test Method / Conditions | |
Drying Temperature ⁷ | 120 | °C | — |
Drying Time ⁷ | 4 | Hrs | — |
Maximum Moisture Content ⁷ | 0.02 | % | — |
Melt Temperature ⁷ | 305 - 325 | °C | — |
Front - Zone 3 Temperature ⁷ | 320 - 330 | °C | — |
Middle - Zone 2 Temperature ⁷ | 310 - 320 | °C | — |
Rear - Zone 1 Temperature ⁷ | 295 - 305 | °C | — |
Mold Temperature ⁷ | 80 - 110 | °C | — |
Back Pressure ⁷ | 0.2 - 0.3 | MPa | — |
Screw Speed ⁷ | 30 - 60 | rpm | — |
Value | Units | Test Method / Conditions | |
UL Recognized (94V-1 Flame Class Rating) ᵖ | min. 3 | mm | UL 94 |
UL Recognized (94V-2 Flame Class Rating) ᵖ | min. 1.5 | mm | UL 94 |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability