Knowde Enhanced TDS
Identification & Functionality
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Performance Benefits
- Dry thin film means no sticky parts
- Fast drying formula. Parts are typically dry in 15 minutes
- Easily removed with moderately alkaline cleaners
- No SARA Title 313 reportable components
- No VOC’s
Applications & Uses
- Markets
- Recommended Applications
- For all application methods, the parts need to be clean and free of soils and oily residues.
- Spray Washer and Dip Application: Oxynul RP-1355 is usually diluted at 10% to 50% by volume in a dip tank or the final stage of a spray or immersion washer. Can be run at ambient temperature or up to 160°F to improve drying time.
- Hand Spraying: Oxynul RP-1355 is typically diluted at 20% to 50% by volume.
Properties
- Physical Form
- Appearance
- Clear solution (10% emulsion), Light amber liquid (Concentrate)
- Characteristics
Value | Units | Test Method / Conditions | |
Specific Gravity (at 16°C) | 8.4 | - | - |
Viscosity (at 40°C) | max. 1.5 | cSt | - |
Film Type | Dry | - | - |
Flash Point | min. 350 | °F | Cleveland Open Cup |
pH (10% Emulsion) | 10.0 | - | - |
Corrosion Protection (15%, Indoor Storage) | 12 - 18 | months | - |
Technical Details & Test Data
- Concentration Control
Refractive Index Multiplier : 5 Refractometer
Reading% Concentration 2 10 4 20 6 30 8 40