Knowde Enhanced TDS
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Performance Benefits
- Low foaming at room temperature.
- Splits out oils for easy skimming and long bath life.
- Leaves parts clean with no tacky residues
- Superior in-process corrosion protection that lasts 4 to 6 weeks eliminating rust stripping operations on processed work.
- Effective cleaner for steel, stainless, cast iron, and titanium
Applications & Uses
- Markets
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Recommended Applications & Dilutions
Concentration Temperature Range
Spray / Flood 5% to 10% 140°F to 170°F Immersion 5% to 10% 140°F to 170°F Ultrasonic 3% to 6% 140°F to 170°F Vibratory 3% to 6% Ambient to 170°F
- Parts coming out of the washer should be blown off using hot air
- Though suitable for multi-metal cleaning, we recommend that yellow metals and some aluminum alloys be rinsed with clean water to remove any residual alkaline residues.
Properties
- Physical Form
- Appearance
- Clear (of Dilution), Clear amber liquid (Concentrate)
- Odor
- Mild
- Characteristics
Value | Units | Test Method / Conditions | |
pH (Typical Operating Range) | 10.0 | — | — |
Density (at 15°C) | 8.7 | lbs/gal | — |
Nitrites | No | — | — |
Silicates | No | — | — |
Phenols | No | — | — |
Technical Details & Test Data
- Concentration Control
Titration Method:
- Titration Factor : 0.78
- Accurately measure 50mL of the in-use fluid into a flask
- Titrate to pH of 4.6 with 0.5N HCl
- Concentration = mL of 0.5N HCl X Titration Factor
mL of 0.5N HCl % Concentration
6.4 5 7.7 6 9 7 10.3 8
Dropper Method:- Dropper Factor : 0.127
- Measure 10mL of the in-use cleaner into a small flask using a 5mL disposable syringe.
- Add 2-4 drops of Bromphenol Blue indicator to the cleaner, swirl to mix. Sample should turn a dark blue.
- Add 0.5N HCl dropwise to until sample turns yellow
- Concentration = Drops of 0.5N HCl X Dropper Factor
Drops of 0.5N HCl % Concentration
40 5 48 6 55 7 63 8
Concentration measurement using a refractometer is not recommended. However, it can be used on fresh charges. The multiplier is 4.63.