Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Application Area
- Application Method
- Bonding Procedure
To use, carefully align parts to be bonded, apply uniform pressure to maintain location. Follow curing guidelines given above. Timing should start once adhesive and substrate reach curing temperature.
- Application Method
- Syringe
Properties
- Typical Properties
- Uncured Properties
- Typical Cured Properties
Value | Units | Test Method / Conditions | |
Minimum Cure Temperature | 100 | °C | - |
Chloride | max. 10 | ppm | - |
Sodium Content | max. 10 | ppm | - |
Potassium Content | max. 10 | ppm | - |
Pot Life | 4 hours | - | - |
Value | Units | Test Method / Conditions | |
Brookfield Viscosity - HAT Viscometer (at 10 rpm at 25°C) | 20000 | cps | - |
Specific Gravity | 1.19 | water 1 | - |
Filler | Silver | - | - |
Percent Silver (cured) | max. 5 | % | - |
Theoretical Coverage (0.001" Wet Thickness) | 25 | in^2/gram | - |
Solid Content | 71 | N/A | - |
Value | Units | Test Method / Conditions | |
Operating Temperature | -55 to +230 | °C | - |
Peak Temperature | 325 | °C | - |
Volume Resistivity (Z Axis) | 0.001 | Ω - cm | - |
Volume Resistivity (X and Y Axis) | 1x10^12 | Ω - cm | - |
Glass Transition Temperature | 100 | °C | - |
Coefficient of Thermal Expansion | 50 | Ppm/°C | - |
T-Shear Strength | 2100 | psi | - |
Weight Loss (at 300°C, TGA) | 2.77 | % | - |
Differential Scanning Calorimetry (DSC) Peak Tc | 168 | °C | - |
Differential Scanning Calorimetry (DSC) ∆ Hc | -33.4 | J/g | - |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Test Data
Safety & Health
- Safety & Handling
- Use with adequate ventilation.
- Keep away from sparks and open flames.
- Avoid prolonged contact with skin and breathing of vapors.
- Wash with soap and water to remove from skin
Storage & Handling
- Shelf Life
- 1 year at ambient temperatures (Part A), 1 year at ambient temperatures (Part B)
- Curing Guidelines
These temperatures and times are presented as a guide only. The curing times are after substrate has been brought up to temperature. The end-user is encouraged to experiment to determine optimum curing schedule.
Temperature (°C) Time (sec.) 175 22-25 200 14 -18 210 4-6 - Handling And Storage
Prior to using, mix thoroughly to re-suspend fillers. If needed, 125-01A/B-187 can be thinned with small amounts of Creative Materials’ 102-03 thinner. Thinning should be done after mixing parts A and B to maintain proper mixing ratio.