Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
Features & Benefits
- Ready-to-Use Product Features
- Key Attributes
- UL94 V-0 approved (File #E334302)
- Excellent bond strength with a wide variety of substrates
- Extreme resistance to vibration and temperature cycles
- Superior tensile, compressive and lap shear strength
- Excellent chemical resistance
- Excellent electrical insulating characteristics
- Low shrinkage
- RoHS 3 compliant
Applications & Uses
- Applications
- Application Area
- Application Method
- Recommended Preparation
Clean the substrate with Isopropyl Alcohol, MG #824, so the surface is free of oils, dust, and other residues.
Syringe or Cartridge
- Twist and remove the cap from the cartridge or syringe. Do not discard cap.
- Dispense a small amount to ensure even flow of both parts.
- (Optional) Attach a static mixer to the 9200FR-50ML.
- Dispense and discard 3 to 5 mL of the product to ensure a homogeneous mixture.
- After use, dispose of static mixer.
- Without a static mixer, dispense material on a mixing surface or container, and thoroughly mix parts A and B together.
- To stop the flow, pull back on the plunger.
- Clean nozzle to prevent contamination and material buildup.
- Replace the cap on the cartridge or syringe.
Dispensing Accessories
Consult the table below for accessory selection. See the Dispensing Accessories Application Guide for usage instructions. 8MT-50-FT should only be used with a pneumatic dispenser.
Cat. No. Dispensing Gun Static Mixer 9200FR-25ML N/A N/A 9200FR-50ML 8DG-50-1-1 8MT-50, 8MT-50FT
Properties
- Thermal Properties
- Typical Properties
- Cured Properties
- Uncured Properties
Value | Units | Test Method / Conditions | |
Thermal Conductivity (at 25 ˚C) | 0.4 | W/(m·K) | — |
Value | Units | Test Method / Conditions | |
Viscosity (at 25 ˚C)ᴬ | 380 | Pa·s | — |
Viscosity (at 25 ˚C)ᴮ | 370 | Pa·s | — |
Value | Units | Test Method / Conditions | |
Breakdown Voltage | 39800 | V | — |
Dielectric Strength | 497 | V/mil | — |
Resistivity | 1.1 x 10¹³ | Ω·cm | — |
Hardness Shore D | 78 | — | — |
Tensile Strength | 13 | N/mm2 | — |
Compressive Strength | 46 | N/mm2 | — |
Lap Shear (Stainless steel) | 14 | N/mm2 | — |
Lap Shear (Aluminum) | 10 | N/mm2 | — |
Glass Transition Temperature (Tg) | 59 | ˚C | — |
CTE Prior Tg | 79 | ppm/˚C | — |
CTE After Tg | 126 | ppm/˚C | — |
Service Temperature Range | 40-150 | ˚C | — |
Value | Units | Test Method / Conditions | |
Mixed Density | 1.34 | g/mL | — |
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
Technical Details & Test Data
- Cure Instructions
Allow to cure at room temperature for 48 hours, or cure the adhesive in an oven at one of these time/temperature options:
Temperature 40 °C 65 °C 80 °C 100 °C Time 16 h 3 h 1.5 h 30 min - Usage Parameters
Working Time 30 min Mix Ratio by Volume 1:1 Mix Ratio by Weight 1:0.92
Packaging & Availability
- Packaging Type
- Packaging and Supporting Products
Cat. No. Packaging Net Volume Net Weight 9200FR-25ML Dual syringe 25 mL 32 g 9200FR-50ML Dual syringe 45 mL 57.7 g
Storage & Handling
- Shelf Life
- 3 Years
- Storage
Store between -10 and 27 ˚C in a dry area, away from sunlight (see SDS). To maximize shelf life, recap product firmly when not in use