Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Key Attributes
- Creates strong permanent electrical connections
- No mixing and unlimited working time
- Low cure temperature of 70 °C
- Room temperature storage
- Suitable for automated dispensing
Applications & Uses
- Applications
- Application Area
- Application Method
- Cure Method
- Recommended Preparation
Clean the substrate with Isopropyl Alcohol, MG #824, so the surface is free of oils, dust, and other residues.
Syringe or Cartridge
- Twist and remove the cap from the cartridge or syringe. Do not discard cap.
- Dispense the adhesive evenly to both surfaces.
- For 30 mL size, insert the cartridge in the 8DG-30-1 dispensing gun (see Dispensing Accessories Application Guide).
- To stop the flow, pull back on the plunger.
- Clean nozzle to prevent contamination and material buildup.
- Replace the cap on the cartridge or syringe.
Dispensing Accessories
Consult the table below for accessory selection. See the Dispensing Accessories Application Guide for usage instructions
Cat. No. Dispensing Gun Static Mixer 9400-3ML N/A N/A 9400-30ML 8DG-30-1 N/A
Properties
- Physical Form
- Physical Properties
- Thermal Properties
- Typical Properties
- Cured Properties
Value | Units | Test Method / Conditions | |
Density | 3.14 | g/mL | — |
Value | Units | Test Method / Conditions | |
Thermal Conductivity (at 25 ˚C) | 4.7 | W/(m·K) | — |
Value | Units | Test Method / Conditions | |
Viscosity (at 25 ˚C) | Thixotropic paste | — | — |
Value | Units | Test Method / Conditions | |
Resistivity | 3.1 x 10⁻⁴ | Ω·cm | — |
Hardness Shore D | 74 | — | — |
Tensile Strength | 2.9 | N/mm2 | — |
Compressive Strength | 18 | N/mm2 | — |
Lap Shear (Stainless steel) | 2.9 | N/mm2 | — |
Lap Shear (Aluminum) | 3.2 | N/mm2 | — |
Glass Transition Temperature (Tg) | 36 | ˚C | — |
CTE Prior Tg | 76 | ppm/˚C | — |
CTE After Tg | 100 | ppm/˚C | — |
Service Temperature Range | -55 to 140 | ˚C | — |
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
Technical Details & Test Data
- Cure Instructions
The product will not cure at room temperature. Cure the adhesive in an oven at one of these time/temperature options:
- 2 h @ 70 ˚C
- 30 min @ 80 ˚C
- Usage Parameters
Working Time Unlimited Cure Times 2 h @ 70 ˚C 30 min @ 80 ˚C
Packaging & Availability
- Packaging Type
- Packaging and Supporting Products
Cat. No. Packaging Net Volume Net Weight 9400-3ML Syringe 3 mL 9.42 g 9400-30ML Cartridge 30 mL 94.2 g
Storage & Handling
- Storage and Handling
Store in a dry area, away from sunlight (see SDS). To maximize shelf life, recap product firmly when not in use and keep frozen. If exposed to freezing temperatures, keep product at room temperature for 2 hours prior to use.
9400-3ML Shelf Life @ 22 ˚C 6 months Shelf Life @ -10 ˚C 1 y 9400-30ML Shelf Life @ 22 ˚C 6 months Shelf Life @ -10 ˚C 9 months