MOCOM Compounds CELLIDOR® CP 400-08 is a base polymer made of cellulose acetate propionate with 8% phthalate-free plasticiser. Pre-drying conditions should be done in an air-circulating dryer for 2-4 hours at a temperature of 60-90°C, depending on the moisture content with a maximum moisture content of 0.15%. For optimal processing performance, injection molding should be done at a melt temperature of 180-230°C and a mold temperature of 40-80°C.

Polymer Name: Cellulose Acetate Propionate (CAP)

Additives Included: Plasticizer (Phthalate-free)

Density: 1210.0 - 1210.0 kg/m³

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Plastics & Elastomers Functions
Technologies

Features & Benefits

Materials Features

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Modulus2000.0MPaISO 178
Flexural Stress (3.5% Strain)54.0MPaISO 178
Tensile Modulus1900.0MPaISO 527
Tensile Stress at Yield45.0MPaISO 527
Tensile Strength at Break42.0MPaISO 527
Tensile Elongation at Break13.0%ISO 527
Impact Strength (Charpy, at 23°C)190.0kJ/m²ISO 179/1eU
Notched Impact Strength (Charpy, at 23°C)15.0kJ/m²ISO 179/1eA
Ball Indentation Hardness (H132/30)77.0MPaISO 2039-1
Physical Properties
ValueUnitsTest Method / Conditions
Density1210.0kg/m³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Vicat B5097.0°CISO 306
HDT / A (1.8 MPa)104.0°CISO 75-1/-2
Typical Properties
ValueUnitsTest Method / Conditions
Moisture Contentmax. 0.15%
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Melt Temperature180 - 230°C
Mould Temperature40 - 80°C
Rheological Properties
ValueUnitsTest Method / Conditions
Melt Index (MVR)3.5cm³/10minISO 1133
MVR Temperature210.0°C
MVR Load2.16kg
Shrinkage (24h)0.8 - 1.1%ISO 294-4

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions
  • In an air circulatIng dryer 60-90 °C for 2-4 h
  • Dependant on moisture content

Storage & Handling

Storage Conditions

Store in dry, protected from light not above 30°C.