company tower banner
MOCOM Compounds Company Logo

ALTECH® PP-H A 2040/159 GF40 CP

1 of 305 products in this brand
MOCOM Compounds ALTECH® PP-H A 2040/159 GF40 CP is a polypropylene homopolymer suitable for injection molding with a melt temperature of 200-270°C and mold temperature of 20-90°C, containing 40 % glass fibers with special features such as chemical coupling, high toughness, and high stiffness. Typical applications are varied and it should be stored in a dry, dark place at a temperature no higher than 30°C. Ensure that it is well sealed to avoid contamination.

Polymer Name: Polypropylene Homopolymer (HPP)

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Fillers Included
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Modulus7600.0MPaISO 178
Flexural Strength135.0MPaISO 178
Tensile Modulus7800.0MPaISO 527
Tensile Strength at Break90.0MPaISO 527
Tensile Elongation at Break3.0%ISO 527
Impact Strength (Charpy, at 23°C)55.0kJ/m²ISO 179/1eU
Impact Strength (Charpy, at -40°C)50.0kJ/m²ISO 179/1eU
Notched Impact Strength (Charpy, at 23°C)12.0kJ/m²ISO 179/1eA
Notched Impact (Charpy, at -40°C)9.0kJ/m²ISO 179/1eA
Physical Properties
ValueUnitsTest Method / Conditions
Density1220.0kg/m³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Vicat B50136.0°CISO 306
HDT / A (1.8 MPa)140.0°CISO 75-1/-2
DSC (Melt Point)166.0°CISO 11357
Flammability
ValueUnitsTest Method / Conditions
Flammability (1.5 mm)HBclassUL 94
UL Recognitionyes
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Mould Temperature20 - 90°C
Melt Temperature200 - 270°C
Rheological Properties
ValueUnitsTest Method / Conditions
Melt Index (MVR)2.0cm³/10minISO 1133
MVR Temperature230.0°C
MVR Load2.16kg
Shrinkage (Lengthwise, 24h)0.2 - 0.4%ISO 294-4
Shrinkage (Lateral, 24h)0.3 - 0.5%ISO 294-4

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions
  • In a dry air (dessiccant) dryer 80-120 °C for 2-3 h
  • In an air circulatIng dryer 80-120 °C for 2-4 h
  • Dependant on moisture content

Storage & Handling

Storage Conditions

Store in dry, protected from light not above 30°C.