Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
Applications & Uses
- Plastics & Elastomers Processing Methods
Properties
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Flammability
- Processing Information (Injection Molding)
- Rheological Properties
Value | Units | Test Method / Conditions | |
Flexural Modulus | 3700.0 | MPa | ISO 178 |
Flexural Strength | 110.0 | MPa | ISO 178 |
Tensile Modulus | 3700.0 | MPa | ISO 527 |
Tensile Strength at Break | 70.0 | MPa | ISO 527 |
Tensile Elongation at Break | 3.0 | % | ISO 527 |
Impact Strength (Charpy, at 23°C) | 19.0 | kJ/m² | ISO 179/1eU |
Notched Impact Strength (Charpy, at 23°C) | 1.5 | kJ/m² | ISO 179/1eA |
Ball Indentation Hardness (H358/30) | 163.0 | MPa | ISO 2039-1 |
Value | Units | Test Method / Conditions | |
Density | 1070.0 | kg/m³ | ISO 1183 |
Value | Units | Test Method / Conditions | |
Vicat B50 | 103.0 | °C | ISO 306 |
HDT / A (1.8 MPa) | 89.0 | °C | ISO 75-1/-2 |
Value | Units | Test Method / Conditions | |
Flammability (1.5 mm) | HB | class | UL 94 |
Flammability (3.0 mm) | HB | class | UL 94 |
Glow Wire (GWFI, 650°C, 1mm) | Passed | — | DIN EN 60695 |
Glow Wire (GWFI, 650°C, 2mm) | Passed | — | DIN EN 60695 |
Glow Wire (GWFI, 650°C, 3mm) | Passed | — | DIN EN 60695 |
Value | Units | Test Method / Conditions | |
Melt Temperature | 210 - 260 | °C | — |
Mould Temperature | 40 - 80 | °C | — |
Value | Units | Test Method / Conditions | |
Melt Index (MVR) | 25.0 | cm³/10min | ISO 1133 |
MVR Temperature | 220.0 | °C | — |
MVR Load | 10.0 | kg | — |
Shrinkage (24h) | min. 0.55 | % | ISO 294-4 |
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- 80 °C in a dry air (dessiccant) dryer for 2-4 h
- 80 °C in an air circulating dryer for 3-6 h
Storage & Handling
- Storage Conditions