Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Additives Included
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Mechanical Properties
Value Units Test Method / Conditions Flexural Modulus 7300.0 MPa ISO 178 Flexural Strength 160.0 MPa ISO 178 Tensile Modulus 8500.0 MPa ISO 527 Tensile Strength at Break 105.0 MPa ISO 527 Tensile Elongation at Break 3.1 % ISO 527 Impact Strength (Charpy, at 23°C) 56.0 kJ/m² ISO 179/1eU Impact Strength (Charpy, at -40°C) 55.0 kJ/m² ISO 179/1eU Notched Impact Strength (Charpy, at 23°C) 10.0 kJ/m² ISO 179/1eA Notched Impact (Charpy, at -40°C) 8.5 kJ/m² ISO 179/1eA - Physical Properties
Value Units Test Method / Conditions Density 1170.0 kg/m³ ISO 1183 - Typical Properties
Value Units Test Method / Conditions Dielectric Constant (εr) 2.813 - - Dielectric Constant (εr) 2.813 - - Dissipation Factor (tan δ) (at 77GHz, 2 mm) 0.013 - - - Thermal Properties
Value Units Test Method / Conditions Vicat B50 145.0 °C ISO 306 HDT / A (1.8 MPa) 160.0 °C ISO 75-1/-2 DSC (Melt Point) 166.0 °C ISO 11357 - Processing Information (Injection Molding)
Value Units Test Method / Conditions Mould Temperature 20 - 70 °C - Melt Temperature 200 - 250 °C - - Rheological Properties
Value Units Test Method / Conditions Melt Index (MVR) 3.5 cm³/10min ISO 1133 MVR Temperature 230.0 °C - MVR Load 2.16 kg - Shrinkage (Lengthwise, 24h) 0.2 - 0.4 % ISO 294-4 Shrinkage (Lateral, 24h) 0.5 - 0.7 % ISO 294-4 Spiral Flow (2 mm wall thickness) 70.0 cm -
Regulatory & Compliance
Technical Details & Test Data
- Product Performance Characteristics
E-Modulus over Different Temperatures
Water/Glycol (50:50) Resistance at 120 °C Over Time
- Pre-Drying Conditions
- In a dry air (dessiccant) dryer 80-120 °C for 2-3 h
- In an air circulatIng dryer 80-120 °C for 2-4 h
Storage & Handling
- Storage Conditions
Store in dry, protected from light not above 30°C.