ELASTOSIL® LR 3003/50 US A/B Liquid Silicone Rubbers are paste-like, easily pigmentable, two-component liquid silicone rubbers with short curing times. These grades are particularly suitable for the large scale, automated production of molded parts.
Processing
ELASTOSIL® LR 3003/50 US A/B can be fabricated using standard liquid rubber injection molding techniques. The product is delivered equal parts A/B and designed for a 1:1 (A;B) mix ratio. With proper metering equipment, it can be pumped directly through a static mixer into the injection molding machine.
Properties
- Physical Form
- Cured Properties
Value Units Test Method / Conditions Brittle Point -73 °C - Density (at 25°C) 1.13 g/cm³ - Dynamic Viscosity (Component A) 700000 mPa·s - Dynamic Viscosity (Component B) 800000 mPa·s - Elongation (at break) 500 % - Pot Life (at 25°C) 48 hours - Shore Hardness A 51 - - Specific Gravity 1.14 g/cm³ - Tear Strength 35 kN/m - Tensile Strength 1500 psi - - Properties
- Excellent catalyzed pot life
- Good mechanical strength
- High transparency
- Fast cure
- Note
Cured Properties : Properties obtained after mixing Part A and Part B in a ratio of 1 : 1; press cured 5 min/166°C, post cure 4 hrs/200°C.
Regulatory & Compliance
Packaging & Availability
- Country Availability
- Packaging Type
- Regional Availability
- Packaging Information
ELASTOSIL® LR 3003/50 US A/B is available in 36 kg. (80 lb.) pail kits and 364 kg. (800 lb.) drum kits.
Storage & Handling
- Shelf Life
- 12 Months
- Storage Information
ELASTOSIL® LR 3003/50 US A/B has a shelf life of at least 12 months when stored below 32°C in the tightly closed original container. Storage beyond the recommended shelf-life does not necessarily mean that the product is no longer usable. However, the properties required for the intended use must be checked for quality assurance reasons. Once opened, containers should always be resealed to prevent catalyst poisoning by amines, sulfur compounds, and other substances.