Value | Units | Test Method / Conditions | |
Flexural Modulus | 4500.0 | MPa | ISO 178 |
Flexural Stress (3.5% Strain) | 54.0 | MPa | ISO 178 |
Tensile Modulus | 3900.0 | MPa | ISO 527 |
Tensile Stress at Yield | 31.0 | MPa | ISO 527 |
Tensile Elongation at Yield | 2.8 | % | ISO 527 |
Tensile Elongation at Break | 5.0 | % | ISO 527 |
Impact Strength (Charpy, at 23°C) | 23.0 | kJ/m² | ISO 179/1eU |
Impact Strength (Charpy, at -40°C) | 12.0 | kJ/m² | ISO 179/1eU |
Notched Impact Strength (Charpy, at 23°C) | 2.0 | kJ/m² | ISO 179/1eA |
Notched Impact (Charpy, at -40°C) | 1.5 | kJ/m² | ISO 179/1eA |
Value | Units | Test Method / Conditions | |
Density | 1220.0 | kg/m³ | ISO 1183 |
Value | Units | Test Method / Conditions | |
Vicat B50 | 100.0 | °C | ISO 306 |
HDT / A (1.8 MPa) | 86.0 | °C | ISO 75-1/-2 |
DSC (Melt Point) | 166.0 | °C | ISO 11357 |
Value | Units | Test Method / Conditions | |
Moisture Content | max. 0.02 | % | — |
Value | Units | Test Method / Conditions | |
Tristimulus Value Y10 of Reflection | 87.0 | % | DIN 5033 |
Tristimulus Value Y10 of Transm.,d=0.5mm | 0.3 | % | ISO 13468 |
Value | Units | Test Method / Conditions | |
Mould Temperature | 20 - 90 | °C | — |
Melt Temperature | 230 - 270 | °C | — |
Value | Units | Test Method / Conditions | |
Melt Index (MVR) | 25.0 | cm³/10min | ISO 1133 |
MVR Temperature | 230.0 | °C | — |
MVR Load | 2.16 | kg | — |
Shrinkage (Lengthwise, 24h) | 0.9 - 1.1 | % | ISO 294-4 |
Shrinkage (Lateral, 24h) | 0.7 - 0.9 | % | ISO 294-4 |
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- In a dry air (dessiccant) dryer 80-100 °C for 2-3 h
- In an air circulatIng dryer 80-100 °C for 2-4 h
Storage & Handling
- Storage Conditions
Store in dry, protected from light.