MOCOM Compounds ALTECH® PA6 A 2015/310 GF15 IM is a Polyamide 6 base polymer, impact modified, heat stabilized, injection molding grade, and nucleated with 15% glass fiber filler/additive system and processing stabilized. For processing injection molding, the melt temperature should be between 270-290°C and mold temperature between 80-100°C. Typical applications include housings, operating elements, impact protection/shock absorbers, and functional components. This product is suitable for the Machinery, Electrical and Electronic, and Automotive market segments. It should be stored in a dry and light-protected environment, not above 30°C, to ensure its optimal performance.

Polymer Name: Polyamide 6 (PA 6)

Functions: Resin

Processing Methods: Injection Molding

Fillers Included: Glass Fiber

Chemical Family: Polyamides

Labeling Claims: Azo Colorants-free, Azo Dyes-free, Conflict minerals-free, PAH-free, PFOA-free, PFOS-free, Persistent Organic Pollutants (POP)-free

Additives Included: Heat Stabilizer, Impact Modifier, Nucleating Agent, Processing Stabilizer

Features: Heat Stabilized, Impact Modified, Nucleated, Processing Stability

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Polymer Name
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Modulus (Dry)3800.0MPaISO 178
Flexural Strength (Dry)130.0MPaISO 178
Tensile Modulus (Dry)4600.0MPaISO 527
Tensile Strength at Break (Dry)84.0MPaISO 527
Tensile Elongation at Break (Dry)4.5%ISO 527
Impact Strength (Dry, Charpy, at 23°C)65.0kJ/m²ISO 179/1eU
Impact Strength (Dry, Charpy, at -40°C)80.0kJ/m²ISO 179/1eU
Notched Impact Strength (Dry, Charpy, at 23°C)20.0kJ/m²ISO 179/1eA
Notched Impact (Dry, Charpy, at -40°C)8.5kJ/m²ISO 179/1eA
Physical Properties
ValueUnitsTest Method / Conditions
Density (Dry)1190.0kg/m³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
HDT / A (Dry, 1.8 MPa)190.0°CISO 75-1/-2
DSC (Melt Point, Dry)221.0°CISO 11357
Typical Properties
ValueUnitsTest Method / Conditions
Moisture Contentmax. 0.15%
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Melt Temperature270 - 290°C
Mould Temperature80 - 100°C
Rheological Properties
ValueUnitsTest Method / Conditions
Shrinkage (Lengthwise, 24h)0.3 - 0.5%ISO 294-4
Shrinkage (Lateral, 24h)0.7 - 0.9%ISO 294-4

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions
  • 80 °C in a dry air (dessiccant) dryer for 2-12 h
  • Dependant on moisture content

Storage & Handling

Storage Conditions

Store in dry, protected from light not above 30°C.