company tower banner
MOCOM Compounds Company Logo

ALCOM® ASA 540/7 UV SV1156-12MCF

1 of 363 products in this brand
MOCOM Compounds ALCOM® ASA 540/7 UV SV1156-12MCF is a base polymer of Acrylonitile/Styrene/Acrylate/Copolymer with a metallic effect similar to RAL 9006, featuring low tendency to flow lines and UV stabilization. It is used for electrical and electronic, building and construction, and sport and leisure applications such as housings.

Polymer Name: Acrylonitrile Styrene Acrylate (ASA)

Processing Methods: Injection Molding

Additives Included: UV Stabilizer

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Additives Included
Chemical Family
Plastics & Elastomers Functions
Technologies

Features & Benefits

Materials Features

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Modulus2900.0MPaISO 178
Flexural Stress (3.5% Strain)74.0MPaISO 178
Tensile Modulus2700.0MPaISO 527
Tensile Stress at Yield49.0MPaISO 527
Tensile Elongation at Yield3.1%ISO 527
Tensile Elongation at Break6.3%ISO 527
Impact Strength (Charpy, at 23°C)35.0kJ/m²ISO 179/1eU
Impact Strength (Charpy, at -40°C)15.0kJ/m²ISO 179/1eU
Notched Impact Strength (Charpy, at 23°C)8.0kJ/m²ISO 179/1eA
Notched Impact (Charpy, at -40°C)2.0kJ/m²ISO 179/1eA
Ball Indentation Hardness (H358/30)97.0MPaISO 2039-1
Physical Properties
ValueUnitsTest Method / Conditions
Density1120.0kg/m³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Vicat B50101.0°CISO 306
HDT / A (1.8 MPa)92.0°CISO 75-1/-2
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Melt Temperature240 - 280°C
Mould Temperature40 - 80°C
Rheological Properties
ValueUnitsTest Method / Conditions
Melt Index (MVR)6.0cm³/10minISO 1133
MVR Temperature220.0°C
MVR Load10.0kg
Shrinkage (24h)0.4 - 0.7%ISO 294-4

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions
  • 80 °C in a dry air (dessiccant) dryer for 2-4 h
  • 80 °C in an air circulating dryer for 3-6 h
  • Dependant on moisture content

Storage & Handling

Storage Conditions

Store in dry, protected from light.