ELASTOSIL® 6100 is a one-component, acid-curing, non-sag silicone sealant for general purpose sealing in do-it-yourself (DIY) applications, especially in sanitary areas. ELASTOSIL® 6100 cures at room temperature in the presence of atmospheric moisture to give a permanently flexible silicone rubber.

Product Type: 1K (1 component) Sealant

Application Area: DIY Applications

Compatible Substrates & Surfaces: Ceramic, Coated Surfaces, Glass

Cure Method: Air Dry, Chemical Cure, Moisture Cure

Chemical Family: Silicones

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Applications & Uses

Application Area
Compatible Substrates & Surfaces
Applications
  • Ready-to-Use Silicone Sealants - General Applications
  • Sealants
  • Silicone Sealants
Application Details

Application Fields

  • DIY applications (car, boat, caravan, house)
  • Sealing in sanitary areas

Processing

  • The substrate areas that will be in contact with the sealant must be clean, dry and free of all loose material such as dust, dirt, rust, oil and other contaminants.
  • Non-porous substrates should be cleaned with a solvent and clean, lint-free, cotton cloth. Remove residual solvent before it evaporates with a fresh clean, dry cloth.
  • It is the user's responsibility to test the compatibility of the sealant with the adjoining materials. Incompatible substances like coating materials (paints, varnishes and glazes) or organic plasticizer containing rubbers (EPDM, butyl and neoprene) can lead to discoloration or other impairments like loss of adhesion of the sealant.
  • Materials in direct contact with the applied sealant like cleaning agents and materials in indirect contact like gaseous emissions can damage the sealant in its function or change its appearance. Because of the multitude of these materials.
  • Wacker cannot make a general statement to the compatibility of materials with the sealant. In case of doubt the user shall conduct appropriate preliminary tests.
  • The time until complete curing may be extended at lower temperature, lower humidity, increasing film thickness or by low volume of air exchange. The use of tooling agents should be avoided if possible. Otherwise, water or a diluted solution of a little neutral soap or alcohol in water should be sparingly applied.

Adhesion

  • ELASTOSIL® 6100 exhibits excellent primerless adhesion to most non-porous siliceous materials (e.g. glass, tiles, ceramics, enamel, glazed tiles) as well as painted, laminated and coated wood.
  • Users must carry out own tests due to the great variety of substrates. The adhesion can be improved in many cases by pretreatment of the substrate with a primer.

Properties

Cured Properties
ValueUnitsTest Method / Conditions
Elongation (at break)150%ISO 8339
Modulus (at 100 % elongation)0.36N/mm²ISO 8339-A
Movement Capability12.5%ISO 11600
Shore Hardness A18ISO 868
Tear Strength4N/mmISO 34, Method C
Tensile Strength (Joint)0.6N/mm²ISO 8339
Uncured Properties
ValueUnitsTest Method / Conditions
Consistency (at 23°C)Non-sagISO 7390, Profile U 20
Density (at 23°C)0.98g/cm³ISO 1183-1 A
Extrusion Mass Flow Rate (at 6 bar, 23°C)800g/min
Skin Formating Time (at 23°C, 50% r.h)25minutes
Properties
  • Suitable for use in sanitary areas
  • Non-sag
  • Readily gunnable both at low (+5 °C) and high (+40 °C) temperatures
  • Rapid crosslinking: quickly becomes tack-free and crack resistant
  • Flexible at low (- 40 °C) and high temperatures (+ 100 °C) following cure.
  • Adheres excellently to glass, vitrified surfaces, ceramic tiles and most coatings.

Regulatory & Compliance

Certifications & Compliance
Restrictions in Use
  • ELASTOSIL 6100 is not compatible with carbonate containing stone e.g. marble and limestone, as the product releases acetic acid during vulcanization.
  • ELASTOSIL® 6100 should not be used on substrates such as concrete, fibrous cement and mortar, as the product releases acetic acid during curing.
  • ELASTOSIL® 6100 should not be used in contact with metals such as lead, copper, brass or zinc due to corrosion.
  • ELASTOSIL® 6100 may be discolored in contact with some organic elastomers, e.g. EPDM and neoprene.
  • ELASTOSIL® 6100 is not recommended for sealing of aquarium or for long term use under water.
  • ELASTOSIL® 6100 should not be used on pre-stressed polyacrylate elements as it may cause environmental stress cracking.
  • ELASTOSIL® 6100 must not be used for insulated- and structural glazing or bonding.
  • ELASTOSIL® 6100 is not suitable for food grade applications where the joints are likely to come in contact with food.
  • ELASTOSIL® 6100 is not suitable for use as a mirror adhesive.

Safety & Health

Safety Note
  • During vulcanization acetic acid is released. These vapors should not be inhaled for long periods or in high concentration. Hence, good ventilation of the work place is necessary.
  • When uncured silicone rubber come into contact with eyes or mucous membranes, the affected area must be rinsed thoroughly with water as irritation will otherwise be caused. Avoid prolonged contact of uncured sealant with the skin - use a dry cloth or paper to remove it. Keep away from children.

Packaging & Availability

Country Availability
Packaging Type
Regional Availability
  • Africa
  • Asia
  • Europe
  • Latin America
  • North America
Packaging Information

ELASTOSIL® 6100 is usually supplied in standard size cartridges that fit all standard caulking guns.