company tower banner
Wacker Chemie AG Company Logo

ELASTOSIL® 5000

1 of 230 products in this brand
ELASTOSIL® 5000 is a one-component, acid-curing, low-modulus silicone sealant with outstanding adhesion, a long shelf life, and very good processing properties for construction and industrial applications. It cures at room temperature in the presence of atmospheric moisture to form a permanently flexible silicone rubber.

Product Type: 1K (1 component) Adhesive, Solventborne Sealant

Compatible Substrates & Surfaces: Ceramic, Coated Surfaces, Glass

Cure Method: Air Dry, Chemical Cure, Moisture Cure

Chemical Family: Silicones

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Labeling Claims

Applications & Uses

Compatible Substrates & Surfaces
Applications
  • ELASTOSIL® - Ready-to-Use Construction Sealants
  • Sealants
Application Details

Application Fields

  • Sealing of joints between glazing and supporting structure (frame, transoms, mullions) in inside- an outside areas
  • Glass sealing
  • Expansion joints in inside- and outside areas

Processing

The substrate areas that will be in contact with the sealant must be clean, dry and free of all loose material such as dust, dirt, rust, oil and other contaminants. Non-porous substrates should be cleaned with a solvent and a clean, lint-free, cotton cloth. Remove residual solvent before it evaporates with a fresh clean, dry cloth.

Adhesion

  • ELASTOSIL 5000 exhibits excellent primerless adhesion to most non-porous siliceous material, e.g. glass, tiles, ceramics, enamel, glazed tiles and clinker Users must carry out their own tests due to the great variety of substances.
  • The adhesion can be improved in many cases by pretreatment of the substrates with a primer.

 

Properties

Color
Physical Form
Cured Properties
ValueUnitsTest Method / Conditions
Elongation (at break)250%ISO 8339
Modulus (at 100 % elongation)0.38N/mm²ISO 8339-A
Movement Capability25%ISO 11600
Shore Hardness A18ISO 868
Tear Strength4.5N/mmISO 34, Method C
Tensile Strength0.7N/mm²ISO 8339
Uncured Properties
ValueUnitsTest Method / Conditions
Consistency (at 23°C)Non-sagISO 7390, Profile U 20
Density (at 23°C)1.01g/cm³ISO 1183-1 A
Extrusion Mass Flow Rate (at 6 bar, 23°C)500g/min
Skin Formating Time (at 23°C, 50% r.h)20minutes
Properties
  • Solvent free
  • Non-sag
  • Ready gunnability at low (+ 5 °C) and high (+ 40 °C) temperatures
  • Low shrinkage on curing
  • Flexible at low (-40 °C) and high temperatures (+100 °C)
  • Low-modulus: better adhesion and higher safety
  • Rapid crosslinking: quickly becomes tack-free
  • Adheres excellently to glass, vitrified surfaces, ceramic tiles, selected plastics and most coatings
  • Excellent tooling properties
  • Long shelf life

Regulatory & Compliance

Certifications & Compliance
Restrictions in Use
  • It is the user's responsibility to test the compatibility of the sealant with the adjoining materials. Incompatible substances like coating materials (paints, varnishes and glazes) or organic plasticizer containing rubbers (EPDM, butyl and neoprene) can lead to discoloration or other impairments like loss of adhesion of the sealant.
  • Materials in direct contact with the applied sealant like cleaning agents and materials in indirect contact like gaseous emissions can damage the sealant in its function or change its appearance.
  • Because of the multitude of these materials. Wacker cannot make a general statement to the compatibility of materials with the sealant. In case of doubt the user shall conduct appropriate preliminary tests.
  • ELASTOSIL® 5000 must not be used for insulating glass applications.
  • ELASTOSIL® 5000 should not be used on substrates such as marble, concrete, fibrous cement and mortar, as the product releases acetic acid during vulcanization.
  • ELASTOSIL® 5000 should not be used in contact with metals such as lead, copper, brass or zinc due to corrosion.
  • ELASTOSIL® 5000 may be discolored in contact with some organic elastomers, e.g. EPDM, APTK and neoprene.
  • ELASTOSIL® 5000 should not be used for sealing of aquaria.
  • ELASTOSIL® 5000 is not recommended for use on natural stone, such as marble, granite, quartzite, as it can cause staining.
  • ELASTOSIL® 5000 is not recommended for structural glazing bonding.
  • ELASTOSIL® 5000 should not be used in contact with metals such as lead, copper, brass or zinc due to corrosion.
  • ELASTOSIL® 5000 is not recommended for sealing of aquaria or for longer-term use under water.
  • ELASTOSIL® 5000 is not suitable for food grade applications where the joints are likely to come in contact with food.
  • ELASTOSIL® 5000 is not suitable for use as a mirror adhesive.
  • The time until complete curing may be extended at lower temperature, lower humidity, increasing film thickness or by low volume of air exchange.
  • The use of tooling agents should be avoided if possible. Otherwise, water or a diluted solution of a little neutral soap or alcohol in water should be sparingly applied.

Safety & Health

Safety Note
  • During vulcanization acetic acid is released. These vapors should not be inhaled for long periods or in high concentration. Hence, good ventilation of the work place is necessary.
  • When uncured silicone rubber come into contact with eyes or mucous membranes, the affected area must be rinsed thoroughly with water as irritation will otherwise be caused. Cured silicone rubber, however, can be handled without any risk to health. Keep away from children.

Packaging & Availability

Country Availability
Regional Availability
  • Africa
  • Asia
  • Europe
  • Latin America
  • North America