Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fluids & Lubricants Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Fluids & Lubricants Features
Applications & Uses
- Markets
- Fluids & Lubricants Type
- Applications
Antifriction Agents & Lubricants
- Application Details
- For practical purposes, the useful temperature range of WACKER® AP 200 is between -35 °C and +200 °C.
- However, this presupposes that heat-stressing of the fluid occurs under "chemically pure" conditions.
- Even trace amounts of acids, alkalis, mineral oils, organometallic compounds, metal salts or metal oxides can seriously reduce the service life. The flash point of the silicone fluid may be changed by heat-stressing.
- It is therefore particularly important in open systems to check the flash point at least once a year and more often if operating conditions demand.
Properties
- Physical Form
- Odor
- Odorless
- Typical Properties
- Properties
- Heat transfer fluid
- Pressure transfer fluid
- Dielectric in capacitors and transformers
- Base fluid of heat resistant lubricants
Value | Units | Test Method / Conditions | |
Density (at 25°C) | approx. 1.07 | g/cm³ | DIN 51757 |
Recommended Service Temperature | -35 to +200 | °C | — |
Dielectric Constant (at 25°C, 100Hz) | approx. 2.9 | — | — |
Dielectric Strength | approx. 20 | kV/mm | — |
Dissipation Factor (tan δ, at 100Hz, 25°C) | approx. 0,0004 | — | — |
Flash Point | approx. 260 | °C | ISO 2719 |
Ignition Temperature | min. 400 | °C | DIN 51794 |
Kinematic Viscosity (at 25°C) | approx. 200 | mm²/s | DIN 51562 |
Refractive Index | approx. 1.50 | — | DIN 51423 |
Specific Heat (at 25°C) | 1.46 J/gK | J/gK | — |
Thermal Coefficient of Expansion (at 0 - 180 °C) | 0.00085 - 0.00082 | mLmL⁻¹K⁻¹ | — |
Thermal Conductivity (at 50°C) | 0.14 | W/m.K | — |
Volatile Content (250°C, 2 hours, 5 g) | max. 1.5 | % | — |
Packaging & Availability
- Country Availability
- Regional Availability