MOCOM Compounds ALCOM® HM PA+ABS 1000 AG 14069 is a hygienic material composed of a Polyamide + Acrylonitrile Butadiene Styrene Blend, available in gray, similar to RAL 7015 and RAL 7042. It has antibacterial properties according to ISO 22196 and can be used for packaging, personal care, furniture, building and construction, and sport and leisure applications.

Polymer Name: PA 6/ABS Alloy

Processing Methods: Injection Molding

Density: 1080.0 - 1080.0 kg/m³

Flexural Modulus: 1900.0 - 1900.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Additives Included
Polymer Name
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Color
Mechanical Properties
ValueUnitsTest Method / Conditions
Flexural Modulus1900.0MPaISO 178
Flexural Stress (3.5% Strain)57.0MPaISO 178
Tensile Modulus1900.0MPaISO 527
Tensile Stress at Yield43.0MPaISO 527
Tensile Elongation at Yield3.1%ISO 527
Tensile Elongation at Break55.0%ISO 527
Impact Strength (Charpy, at 23°C)no breakkJ/m²ISO 179/1eU
Impact Strength (Charpy, at -40°C)no breakkJ/m²ISO 179/1eU
Notched Impact Strength (Charpy, at 23°C)65.0kJ/m²ISO 179/1eA
Notched Impact (Charpy, at -40°C)8.5kJ/m²ISO 179/1eA
Ball Indentation Hardness (H358/30)87.0MPaISO 2039-1
Physical Properties
ValueUnitsTest Method / Conditions
Density1080.0kg/m³ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Vicat B50106.0°CISO 306
HDT / A (1.8 MPa)63.0°CISO 75-1/-2
Typical Properties
ValueUnitsTest Method / Conditions
Moisture Contentmax. 0.12%
Flammability
ValueUnitsTest Method / Conditions
Flammability (1.5 mm)HBclassUL 94
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Melt Temperature250 - 270°C
Mould Temperature50 - 80°C
Rheological Properties
ValueUnitsTest Method / Conditions
Melt Index (MVR)63.0cm³/10minISO 1133
MVR Temperature240.0°C
MVR Load10.0kg

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions

80 °C in a dry air (dessiccant) dryer for 2-12 h

Storage & Handling

Storage Conditions

Store in dry, protected from light tightly sealed.