company tower banner
MOCOM Compounds Company Logo

Alcom® TCD PA6 5060 FR 15090

1 of 363 products in this brand
MOCOM Compounds Alcom® TCD PA6 5060 FR 15090 is a polyamide 6 (PA6) material that contains a special filler system, making it thermally conductive, electrically insulating, and halogen-free flame retardant. It is also opaque and heat stabilized, making it suitable for use in radiator systems and cooling systems in the automotive, machinery, electrical and electronic, and lighting industries.

Polymer Name: Polyamide 6 (PA 6)

Processing Methods: Injection Molding

Fillers Included: Mineral, Proprietary

Additives Included: Flame Retardant, Heat Stabilizer

Flexural Modulus: 9500.0 - 9500.0 MPa

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Fillers Included
Polymer Name
Plastics & Elastomers Functions
Technologies

Features & Benefits

Applications & Uses

Plastics & Elastomers Processing Methods

Properties

Physical Properties
ValueUnitsTest Method / Conditions
Density1630.0kg/m³ISO 1183
Mechanical Properties
ValueUnitsTest Method / Conditions
Impact Strength (Charpy, at 23°C)30.0kJ/m²ISO 179/1eU
Flexural Modulus9500.0MPaISO 178
Flexural Strength140.0MPaISO 178
Tensile Elongation at Break1.5%ISO 527
Tensile Modulus10000.0MPaISO 527
Tensile Strength at Break80.0MPaISO 527
Thermal Properties
ValueUnitsTest Method / Conditions
HDT / A (1.8 MPa)175.0°CISO 75-1/-2
DSC (Melt Point)220.0°CISO 11357
Thermal Conductivity (integral)1.0W/(m K)ISO 22007-2
Specific Heat Capacity1.49J/gK
Thermal Conductivity (in-plane)1.5W/(m K)ASTM E 1461
Thermal Conductivity (through-plane)1.0W/(m K)ASTM E 1461
Vicat B50215.0°CISO 306
Typical Properties
ValueUnitsTest Method / Conditions
Moisture Contentmax. 0.12%
Electrical Properties
ValueUnitsTest Method / Conditions
Dielectric Strength27.0kV/mmIEC 60243-1
Surface Resistance1 x 10¹²OhmDIN EN 62631-3-2
Tracking Resistance (CTI)600.0IEC 60112
Flammability
ValueUnitsTest Method / Conditions
Glow Wire (GWFI, 960°C, 1mm)PassedDIN EN 60695
Flammability (1.5 mm)V - 2classUL 94
Processing Information (Injection Molding)
ValueUnitsTest Method / Conditions
Mould Temperature100 - 120°C
Melt Temperature280 - 300°C
Rheological Properties
ValueUnitsTest Method / Conditions
Shrinkage (Lengthwise, 24h)0.7 - 1.1%ISO 294-4
Shrinkage (Lateral, 24h)0.5 - 0.9%ISO 294-4
Spiral Flow (2 mm wall thickness)23.0cm

Regulatory & Compliance

Technical Details & Test Data

Pre-Drying Conditions

80 °C in a dry air (dessiccant) dryer for 2-12 h

Technical Data

Storage & Handling

Storage Conditions

Store in dry, protected from light.