Value | Units | Test Method / Conditions | |
Density | 1630.0 | kg/m³ | ISO 1183 |
Value | Units | Test Method / Conditions | |
Impact Strength (Charpy, at 23°C) | 30.0 | kJ/m² | ISO 179/1eU |
Flexural Modulus | 9500.0 | MPa | ISO 178 |
Flexural Strength | 140.0 | MPa | ISO 178 |
Tensile Elongation at Break | 1.5 | % | ISO 527 |
Tensile Modulus | 10000.0 | MPa | ISO 527 |
Tensile Strength at Break | 80.0 | MPa | ISO 527 |
Value | Units | Test Method / Conditions | |
HDT / A (1.8 MPa) | 175.0 | °C | ISO 75-1/-2 |
DSC (Melt Point) | 220.0 | °C | ISO 11357 |
Thermal Conductivity (integral) | 1.0 | W/(m K) | ISO 22007-2 |
Specific Heat Capacity | 1.49 | J/gK | — |
Thermal Conductivity (in-plane) | 1.5 | W/(m K) | ASTM E 1461 |
Thermal Conductivity (through-plane) | 1.0 | W/(m K) | ASTM E 1461 |
Vicat B50 | 215.0 | °C | ISO 306 |
Value | Units | Test Method / Conditions | |
Moisture Content | max. 0.12 | % | — |
Value | Units | Test Method / Conditions | |
Dielectric Strength | 27.0 | kV/mm | IEC 60243-1 |
Surface Resistance | 1 x 10¹² | Ohm | DIN EN 62631-3-2 |
Tracking Resistance (CTI) | 600.0 | — | IEC 60112 |
Value | Units | Test Method / Conditions | |
Glow Wire (GWFI, 960°C, 1mm) | Passed | — | DIN EN 60695 |
Flammability (1.5 mm) | V - 2 | class | UL 94 |
Value | Units | Test Method / Conditions | |
Mould Temperature | 100 - 120 | °C | — |
Melt Temperature | 280 - 300 | °C | — |
Value | Units | Test Method / Conditions | |
Shrinkage (Lengthwise, 24h) | 0.7 - 1.1 | % | ISO 294-4 |
Shrinkage (Lateral, 24h) | 0.5 - 0.9 | % | ISO 294-4 |
Spiral Flow (2 mm wall thickness) | 23.0 | cm | — |
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
80 °C in a dry air (dessiccant) dryer for 2-12 h
- Technical Data
Storage & Handling
- Storage Conditions
Store in dry, protected from light.