company tower banner
Wacker Chemie AG Company Logo

ELASTOSIL® E43 Transparent

1 of 230 products in this brand
ELASTOSIL® E43 Transparent is a self-leveling, one-component acetoxy-cure silicone rubber that cures at room temperature under the influence of atmospheric moisture. It shows excellent mechanical properties and has good adhesion properties to many substrates. In particular, it is used as adhesive on cured silicone rubber.

Product Type: 1K (1 component) Adhesive, Solvent free (100% Solids) Sealant, Solventborne Adhesive

Application Area: Form In Plastic Gaskets (FIPG), Gaskets, White Goods

Cure Method: Air Dry, Chemical Cure, Moisture Cure

Chemical Family: Silicones

Technical Data Sheet

Knowde Enhanced TDS

Identification & Functionality

Chemical Family

Features & Benefits

Labeling Claims
Special Features
  • Excellent mechanical properties
  • Solvent-free

Applications & Uses

Applications
  • Aerospace
  • Appliances Industry
  • Appliances Industry
  • Bonding, Fixing & Sealing
  • Industrial Adhesives
  • Small Appliances
Application Details

Multipurpose sealant and adhesive for general industry and electronics for FIPG applications. Particularly suitable as adhesive on cured rubber or silicone coated textiles like seam sealing.

Processing

  • ELASTOSIL® E43 is a ready-to-use, one-part silicone rubber which starts curing when exposed to air moisture.
  • As RTV-1 silicones require humidity for curing, free access of air moisture to the silicone rubber is essential. Additionally, the vulcanization time of ELASTOSIL® E43 can be greatly reduced by increasing the level of air's relative humidity. Please note that, unlike the initial skin formation, the total curing rate of RTV-1 silicones is limited by moisture's diffusion speed in silicone rubber.
  • As increasing the curing temperature has just a minor effect both on the skin forming time and the curing speed, ELASTOSIL® E43 typically is vulcanized at room temperature. Heat curing is recommended only for applications where the silicone rubber is applied as a thin film (thickness less than 0.5 mm), because otherwise blistering is likely to occur due to the quick release of acetic acid.
  • After completion of the vulcanization the silicone elastomer may continuously be exposed to constantly changing climatic conditions, UV radiation and high temperature without damage.
  • Cured ELASTOSIL® E43 usually shows good primerless adhesion to many substrates, e.g. glass, ceramics, metals, plastics and powder coatings. Removal: If removal of the silicone from machines or dispensing equipment is necessary, white spirit or similar nonpolar solvents are recommended.
  • However, cleaning ideally should take place before the silicone rubber is fully vulcanized. Cured silicone needs to be rubbed off or removed mechanically, if necessary in combination with a swelling agent (solvent) or a chemical silicone remover ELASTOSIL E43 shows good primerless adhesion to many substrates. We recommend running preliminary tests to optimize conditions for the particular application.

 

Properties

Cured Properties
ValueUnitsTest Method / Conditions
Density (in water, at 23°C)1.1g/cm³DIN EN ISO 1183-1 A
Elongation (at break, Type 3, 23°C, 2mm)500%ISO 37 Type 1
Shore Hardness A30DIN ISO 48-4
Tensile Strength (Type 3, at 23°C, 2mm)6.5N/mm²ISO 37 Type 1
Uncured Properties
ValueUnitsTest Method / Conditions
Curing Time (at 23°C, 50 %r.h)12hour/mm
Density (at 20°C)1.09g/cm³DIN EN ISO 2811-1
Dynamic Viscosity (at 25°C, Shear rate 0.5 s⁻¹)250000mPa·sDIN EN ISO 3219
Dynamic Viscosity (at 25°C, Shear rate 25 s⁻¹)175000mPa·sDIN EN ISO 3219
Skin Formating Time (at 23°C, 50% r.h)10minutes
Properties
  • Moderately self-leveling
  • High-tear grade
  • Recommended service temperature from -45 °C to +180 °C
  • Max. Recommended short term peak temperature exposure 200°C
Note

Curing Conditions: 14 days at 23 °C and 50 % rel. humidity, 2 mm sheet, no post-curing for cured properties.

Regulatory & Compliance

Certifications & Compliance

Safety & Health

Safety Note

During vulcanization of ELASTOSIL® E43 TRANSPARENT, a total of 4% by weight of acetic acid is split off. These vapors should not be inhaled for long periods or in high concentration. Work areas should therefore be well ventilated. Contact of unvulcanized silicone rubber with eyes and mucous membranes must be avoided as this would cause irritation. However if it does happen, rinse the affected area thoroughly with water.