Knowde Enhanced TDS
Identification & Functionality
- Carrier
- Chemical Family
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Specific Features
- Acetoxy-cure
- Condensation-curing
- Flowable
- Heat resistant
- One-component
- Self-leveling
- Solvent-free
Applications & Uses
- Applications
- Application Area
- Cure Method
- Applications
- Appliances Industry
- Bonding & Sealing
- Household Applications
- Industrial Assembly
- Ready-to-Use Silicone Sealants - General Applications
- Small Appliances
- White Goods
- Application Details
High temperature resistant grade for sealing and bonding applications under high thermal stress. Use e.g. for sealing of steam chambers and sole plates of steam irons.
Processing
ELASTOSIL® E70 shows good primerless adhesion to many substrates. We recommend running preliminary tests to optimize conditions for the particular application.
Properties
- Cured Properties
- Uncured Properties
- Properties
- Acetoxy-cure grade
- Self leveling properties
- max. recommended short term peak temperature 230°C
Value | Units | Test Method / Conditions | |
Density (in water, at 23°C) | 1.24 | g/cm³ | DIN EN ISO 1183-1 A |
Recommended Service Temperature | -45 to 200 | °C | — |
Elongation (at break, 23°C, t=2mm) | 250 | % | ISO 37 Type 1 |
Shore Hardness A | 40 | — | DIN ISO 48-4 |
Tensile Strength (at 23°C, t=2mm) | 3.5 | N/mm² | ISO 37 Type 1 |
Value | Units | Test Method / Conditions | |
Curing Time (at 23°C, 50 %r.h) | 12 | hour/mm | — |
Density (at 23°C) | 1.22 | g/cm³ | DIN 53217 |
Skin Formating Time (at 23°C, 50% r.h) | 15 | minutes | — |
Viscosity (at 25°C, Shear rate 0.5 s⁻¹) | 75000 | — | ISO 3219 |
Viscosity (at 25°C, Shear rate 25 s⁻¹) | 60000 | — | ISO 3219 |
Regulatory & Compliance
- Certifications & Compliance
Safety & Health
- Safety Notes
During vulcanization of ELASTOSIL® E70, a total of 3% by weight of acetic acid is split off. These vapors should not be inhaled for long periods or in high concentration. Work areas should therefore be well ventilated. Contact of unvulcanized silicone rubber with eyes and mucous membranes must be avoided as this would cause irritation. However if it does happen, rinse the affected area thoroughly with water.
Packaging & Availability
- Country Availability